MySQLERRORNotableReplicationHIGH confidence
Binlog logical clock conflict
Production Risk
High — replication halted or inconsistent.
What this means
The binlog logical clock used for parallel replication (LOGICAL_CLOCK dependency tracking) detected a conflict, preventing a transaction from being applied in parallel.
Why it happens
- 1Two transactions have conflicting lock dependencies that prevent safe parallel execution under LOGICAL_CLOCK mode.
How to reproduce
trigger — this will error
trigger — this will error
-- Internal error during MTS LOGICAL_CLOCK scheduling; not directly triggerable
expected output
ERROR 1799 (HY000): Logical clock conflict detected during parallel replication.
Fix
Switch slave_parallel_type to DATABASE to avoid LOGICAL_CLOCK conflicts
Switch slave_parallel_type to DATABASE to avoid LOGICAL_CLOCK conflicts
STOP SLAVE; SET GLOBAL slave_parallel_type = 'DATABASE'; START SLAVE;
Why this works
DATABASE-based parallelism is less aggressive but avoids logical clock conflicts.